Meet Buddy, your new spirometry coach
ndd Medical Technologies

EasyOne Pro

Portable DLCO, Lung Volumes and Spirometry
EasyOne Pro provides the most efficient and accurate way to test lung function in various settings. Engineered using our patented TrueFlow™ and TrueCheck™ technology, the EasyOne Pro eliminates all common sources of error, saves time and gives your patients the best pulmonary care in your practice or lung function lab. No need for a Body Box.

Why our customers love us

  • We are over-the-top satisfied with ndd’s EasyOne Pro.

    The EasyOne Pro is easy to use, easy to assemble, and is great for large and claustrophobic patients. The EasyOne Pro saves a huge amount of floor space, and it’s portable.

    We’ve had many patients say they will never go back to the surrounding hospitals because of the convenience of testing with ndd’s EasyOne Pro (and the fact that they don’t have to enter that uncomfortable PFT body box).

    Sarah Raile
    RRT /Wray Hospital and Clinic - Banner Health
  • The pulmonologist that tests at our facility is impressed with the EasyOne Pro, as the testing results are spot-on with a similar PFT test done in a traditional body box. We would go with the Pro over a traditional body box any day.
    Sarah Raile
    RRT /Wray Hospital and Clinic - Banner Health
  • We recently acquired several EasyOne Pros for three hospitals in Madrid. Given the current situation [COVID-19], this equipment guarantees proper cleaning & disinfection between patients. In addition, it’s very easy to use, something the Team very much appreciates - it’s portable, and it brings the highest accuracy. An excellent medical device.
    Dr. Rodríguez-Moro
    Principe de Asturias University Hospital
  • Being on a truck we really like equipment that can be mobilized. It has to be small, it has to be able to be moved around without breaking, it has to be reliable. When I did the research, the EasyOne Pro was being used in that capacity for other outreach clinics and I thought we should invest in that for our trucks. It has been a great decision actually. It’s very easy to use, reliable and accurate.
    Dr. Rolf Gomes
    Founder of Heart of Australia & Cardiologist
  • We see that ndd technology is always accurate when comparing it to simulator data or biological control values. In addition to the outstanding accuracy the ndd software is very user-friendly, which makes ndd devices easy to use.
    Alejandro Casas MD, Ph.D
    General Director, Colombian Pulmonological Foundation /Former President, ALAT (Latin American Thoracic Association)
  • My clinical research on asthma and COPD happens at the point of care in some of the most remote, resource limited places in the world. Because of this, I need highly portable, very durable diagnostic devices reporting consistent and accurate results even under the toughest conditions. I use ndd’s devices because I know no matter the condition, the device will report accurate results.
    William Checkley, MD
    Associate professor at John Hopkins Bloomberg School of Public Health
  • Our academic activities related to trainings and continuous learning for the specialists that take care of the respiratory health in our region, are supported by new technologies. Our experience with ndd devices has been very positive because they adapt to our necessities, they are always updated regarding new standardization and technological advances.
    Gustavo Giraldo
    Public Relations and Marketing Manager /Asociación Latinoamericana de Tórax (ALAT)
  • The EasyOne Pro’s portability and ability to accurately perform mobile PFTs in under 30 minutes make it the perfect device for this type of clinic. It allows us to use the patients’ time more efficiently, better understand their illness, and improve assessment of their condition. It’s easy to operate and allows us to provide prompt and accurate assessment of patients’ lung function.
    Anoop Nambiar, MD
    Medical Director of the San Antonio Pulmonary Fibrosis Support Group and Director of the University of Texas Health Science Center at San Antonio Center for Interstitial Lung Disease.
  • Patients are surprised and impressed at the sophistication of our device and that we can do such comprehensive pulmonary function testing in their homes, for some of them it’s an ordeal to get transportation to a PFT testing site. For others, they’re unable to afford transportation. They are so happy and appreciative that we come to their homes.
    Robin Contino
    American Respiratory Labs

Testing at the Point of Care

Get maximum efficiency and patient comfort. TrueFlow™ and TrueCheck™ ensure optimal results, independent of the clinician.

  • Always safe & ready to test with TrueCheck™
  • Diffusion capacity results in 3 minutes
  • User- and patient-friendly design
  • Ideal also for claustrophobic and obese patients

QC-Grading and Result Interpretation

Get automatic quality grading and interpretation based on NLHEP and ATS/ERS with the EasyOne Pro.

  • Quality grades based on NLHEP and ATS/ERS 2005 and 2019 for all tests
  • ATS/ERS interpretation decision tree
  • GOLD/Hardie, NICE, JRS and NLHEP
  • Diagnose Asthma, COPD, Emphysema and pulmonary vascular disorders

Custom Provocation Protocols

Customize available standard provocation protocols for your needs or create your own. You can easily install the customized provocation protocol on your ndd devices.

  • Build your own provocation protocols
  • Modify existing provocation protocols
  • Export and load protocols onto other devices

Pre-installed protocols: Mannitol, MC, Exercise Provocation
Watch our video guide for more details.

Provocation Protocols

TrueCheck™ – Always Safe & Ready to Test

TrueCheck™ takes care of the essential quality control for gas analysis testing. EasyOne Pro is the only device proven to be accurate for a lifetime for DLCO measurements.

  • Calibration-free with proven long-term stability
  • Checks gas-sensor linearity and delay
  • Checks for leaks and gas concentration
  • Patented technology

To review case studies and additional information about our proven technology, please click here.

TrueFlow™ - Trusted Ultrasound Technology

Stop worrying about calibration or accuracy of flow measurements. TrueFlow™ is the only ultrasound technology proven to be accurate for a lifetime for flow and volume measurements.

To review case studies and additional information about our proven technology, please click here.

TrueFlow™ - Trusted Ultrasound Technology

Infection Control

ndd inline filter solutions provide additional COVID-19 protection for those who wish to include a filter when performing tests.

  • The filter keeps the ambient environment clean for technicians and patients
  • The Spirette protects the flow sensor from contamination
  • Fully passes 24 Waveform tests as required by the ATS/ERS standard

Avoid cross-contamination and reduce cleaning to an absolute minimum:

  • All parts exposed to the patient’s breath are single-patient-use
  • Sensor is protected from contamination by ndd breathing mouthpiece
  • Only simple surface cleaning required of the device
  • No special storage conditions required for single-patient use Spirettes and adapters
Elderly Woman Wearing Mask

EMR/EHR Connectivity and Centralized Datav

Transmit and share data among ndd devices or to your Electronic Medical Record system.

  • Integrated into all major EMR/EHR systems via HL7, XML, GDT or API
  • References for integration available on request
  • Simple local or SQL server database
  • Review test results from any PC using EasyOne Connect

Printer and Network Connectivity

Stay connected and easily share data or print reports. EasyOne Pro is equipped with a modern embedded PC solution that makes network and printer connections extremely easy and stable.

  • USB / Network printer compatibility
  • Easily integrate into any network
  • USB, HDMI, Ethernet
  • Optional WiFi dongle
EasyOne Pro LAB back

Cyber Security Protection for IT and Patient Information

Protect your patient information. EasyOne Pro is a modern system designed to fulfill your cyber security needs.

  • Windows Defender Antivirus and Firewall
  • Operating system updates
  • Encrypted database export
  • User authentication with automatic log off
  • FDA Approval in 2017 with cyber security documentation
FDA HIPPA logo

Analysis and Recording of Raw Sensor Data

Go beyond normal lung function testing and get access to all raw data of any test collected. The tool WBreath is used in special study setups, but also by our support team.

  • Access and measure raw data
  • Advanced Data Analysis
  • Fully integrated

Worldwide Compliance with Standards

Stay compliant with ATS/ERS standards and specific country regulations.

  • Full compliance with ATS/ERS 2005 and 2019 and relevant ISO standards
  • Registrations across the globe
  • CE Approval
  • US FDA cleared to market
ATS/ERS logo

Downloads

You will see available downloads after providing your location.

Software
Software

Application Notes
Application Notes

Brochures
Brochures

Certificates
Certificates

Manuals
Manuals

FAQs

  • Which EHR vendors can ndd integrate with?

    ndd can integrate with any EHR vendor that can support a bi-directional HL7 orders/results lab interface.

  • What kind of integration options does ndd offer?

    ndd offers a file-based integration utilizing an SFTP or network-based location for file communication with an EHR vendor. HL7 is the standard data structure that ndd utilizes but can support other data formats as well. The use of other interface engines can be utilized to complete an integration project.

  • What is the process for integrating your software with our existing systems?

    The first step for an integration project is to complete the EMR integration request form here: https://nddmed.com/f/emr. An integration specialist will then reach out to you with the next steps.

  • How long does the integration process typically take?

    Duration depends on the IT team of the facility. The ndd side of the integration process can be completed within a few hours for standard integrations. EasyOne Connect software is simply configured to point to the SFTP or network-based location where files are being placed.

  • How does ndd ensure that data is securely transferred during integration?

    EasyOne Connect software utilizes AES 256 encryption. SFTP has its own security protocols built into it. If a network-based location is utilized, it will follow the protocols of the facility.

  • Can patient data and test results be accessed across multiple laptops and desktops within a clinic?

    Yes, EasyOne Connect offers an optional centralized patient database feature, enabling seamless access to patient orders and results across all instances of the software, irrespective of physical location. Customers can leverage their on-premise SQL servers or MS Azure environments to ensure data accessibility and consistency.

  • Does ndd offer user management within the software?

    EasyOne Connect provides flexible options for managing users and their access. User accounts can be created and managed directly within EasyOne Connect for simple permission control. For more advanced management, the software supports integration with Active Directory for using your existing directory service accounts, groups, and permissions. EasyOne Connect also supports optional single sign-on (SSO) capability. If you would like to review the Active Directory Application Note, please contact [email protected].

  • Can ndd provide examples of successful integration with other clients?

    ndd has integrated with all major vendors and can provide examples of successful integrations with various healthcare providers and organizations. You can contact our integration department via email at [email protected] for more information.

  • How does ndd handle updates and maintenance to the integration?

    ndd does not handle the maintenance and upgrades as the software is installed locally on the client’s machine. We do, however, offer a silent installer package that our support team can assist you with. This silent installer can be executed via a script through active directory commands depending on your facility. It is the responsibility of the facility to implement any future updates. There is no licensing fee associated with the software and/or the updates.

  • Are there any additional costs associated with integration?

    ndd does not charge for standard integration. In the event custom development is needed, ndd will provide a statement of work before a project begins. Almost all EHR vendors will charge a fee that the client is responsible for.

  • What are the HL7 specifications?

    HL7 specifications can be found here.

  • What are the database options?

    1. Local SQLite file-based database.
    2. On-premise Microsoft SQL Server database.
    3. Azure cloud-hosted Microsoft SQL Server database.

    Please see the application note for additional information.

  • Who is responsible for setting up and hosting the SFTP and/or network-based location?

    The facility is responsible for setting up and hosting either option. ndd requires a username and password if using an SFTP environment.

  • What results are received in the HL7 message?

    The result HL7 message will consist of a combination of discrete results and an embedded base64 PDF attachment for the PFT report. If you prefer, we also offer the option of including a reference link instead of the embedded PDF.

  • Is a server required?

    No, a server is not required.

  • What kind of support does ndd offer during and after the integration process?

    You can schedule a meeting with an integration engineer from 8 a.m. to 5 p.m. ET Monday through Friday. ndd can accommodate meetings outside of that timeframe if planned accordingly. The integration team can be reached via email at [email protected]. The support team can also be reached via email at [email protected] or by phone at (978) 470-0923.

  • What is the difference between the EasyOne Pro and Pro LAB?

    The EasyOne Pro LAB is exactly the same as the EasyOne Pro, except that it has the capability to perform the multi-breath washout (MBW) test. This test requires additional sensors and the use of 100% Oxygen.

  • How to connect a filter to the EasyOne Pro/LAB

    To add a filter (2) to the EasyOne Pro, insert the (1) Spirette FA Pro/LAB into the EasyOne Pro handle. Then attach the filter to the Spirette FA Pro/LAB, as shown in the diagram below. If you have questions about how to connect or use ndd filters, please contact ndd customer support in North America at [email protected] and internationally at [email protected].

    EasyOne Pro LAB inline filter solution

  • Which predicted or normal values are supported?

    You can find the product specification on the respective product pages. The specification contains a list of all supported normal values.

    To get more detailed information about the supported parameters, age range, ethnicities and height range of each supported predicted set, please click here.

  • How do you derive DLadj (DLCO adjustment)?

    The DLCO value can be adjusted for hemoglobin, altitude and the COHb concentration and CO back pressure.

    Click here to find more information about the formulas used to derive DLadj.

  • What is BTPS and how is it used?

    BTPS Correction is used to convert flow and volume measured at ambient conditions to the conditions within the lungs. Ambient conditions are called ATP (ambient temperature, pressure); the conditions within the lungs are called BTPS (body temperature, pressure, water vapor saturated).

    Click here for more information.

  • Can the EasyOne Pro/LAB be connected to my network for backup and data sharing?

    Yes. Connecting the device to your network allows several additional benefits.

    o Take advantage of your network data backup processes

    o Print directly to your network printers

    o Save reports electronically (such as PDF) directly to a network folder

    o Connect with your EMR system

    o Take advantage of a more powerful SQL Server database engine (click herefor more detailled instructions)

    o Connect multiple devices to a single, shared database

    o Get access to the device database from your PC using our free EasyOne Connect PC software application

  • Do I need any special calibration equipment for the EasyOne Pro/LAB?

    All EasyOne products are designed to require no calibration and minimal maintenance. The device is designed to remain in calibration throughout its lifetime. No calibration procedures are required prior to testing. Our TrueFlow ultrasonic technology assures accurate volume and flow measurements every time. And our unique automated TrueCheck process assures that all gas measurements are accurate for each test. You may choose to use the optional 3-liter calibration syringe to verify volume and flow accuracy, as recommended by ATS/ERS.

  • How long does it take to test a patient with the EasyOne Pro/LAB?

    A PFT session including spirometry and DLCO generally takes less than 20 minutes.

  • What are my options for printing results from the EasyOne Pro/LAB?

    The EasyOne Pro/LAB is compatible with virtually all PC-style USB printers, without the need for external driver installation. The printer can be connected directly to a USB port on the rear of the device. We can sell you a printer with the device, or you can supply your own.

    You can also connect the device to your network where it will automatically find any connected, compatible printers avoiding the need for a dedicated printer for your PFTs.

  • What consumables are required for the EasyOne Pro/LAB?

    Spirette: Each test performed requires the use of a spirette. This is a single-patient-use mouthpiece which ensures that no contamination can reach the internal flow path of the device. This means that no cleaning is required between patients, and no calibration, ever. Simply toss the spirette after each test session.

    Barriette: For a DLCO test, in addition to the spirette, you will need to use a barriette. This protects the valve and hose system from contamination, eliminating the need for cleaning between patients.

    FRC barriette: This is similar to the DLCO barriette, but used only when performing a multi-breath washout test.

    Gasses: The DLCO test requires a standard medical grade DLCO gas mixture consisting of 0.3% Carbon Monoxide, 10% Helium, 21% Oxygen, remainder Nitrogen. The multi-breath washout test requires 100% Oxygen. These gasses are readily available from your local medical gas supplier in various tank sizes. We will assist you in selecting the appropriate tank regulators required for connection to the device.

  • How much space will an EasyOne Pro/LAB require in my office?

    The device itself is self-contained and measures only 270 x 335 x 270 mm (10.6 x 13.2 x 10.6 inches) (h x w x d). No additional PC, monitor, keyboard or control unit is required. This allows it to easily fit on a counter. You will also need to allow for storage of the gas tank(s) which come in a variety of sizes, and can usually fit comfortably in a corner, or under the counter.

  • What are the maintenance requirements for the EasyOne Pro/LAB?

    The EasyOne Pro/LAB is designed to require minimal maintenance. The annual replacement of four external components is ALL that is required to keep the system running smoothly. These components are available as a convenient kit. Installation is done in minutes and requires no special tools.

  • How do I backup my patient data?

    Data can safely be exported by using the “Export Data” feature or “Backup” feature within the Storage tab in the configuration.

Specifications

  • Standards & Recommendations

    Quality, Medical Devices & Electrical
    ISO 13485, ISO 14971, IEC 62366, IEC 62304, ISO 26782, ISO 23747, IEC60601-1, IEC 60601-1-2, ISO 10993-1
    FDA
    510(k) market clearance
    MDD 93/42/EEC
    CE marked
    Associations & Institutes
    ATS/ERS 2019 and 2005, NIOSH/ OSHA, SSA Disability
  • Languages

    Graphical user interface
    Brazilian Portuguese, Chinese, Croatian, Danish, Dutch, English, Finnish, French, German, Italian, Japanese, Norwegian, Portuguese, Russian, Spanish, Swedish, Turkish, Vietnamese
  • Gas specification

    DLCO
    9% to 11% medical grade helium
    0.27% to 0.33% medical gradecarbon monoxide
    18% to 25% medical grade oxygenbalance nitrogen
    The DLCO test requires a gas mixturewithin an accuracy range of <2%
  • Technical

    Printing options
    PCL standard, direct to printer or over network
    Data management
    EasyOne Connect (SQLite, MS SQL Server)
    Export
    HL7, XML, GDT, via USB, LAN Network
    Data links
    Ethernet port, USB, possibility to upgrade to WLAN
    No. of tests
    > 10‘000 tests
    Age range
    Spirometry > 4 years, DLCO > 6 years
    Dimensions
    27 x 33.5 x 27 cm3 (H x W x D), 8 kg
    Device classification
    Protection class I, Type BF applied part
    Operating conditions
    Temp 5 - 40 °C/41 - 104 °F, Rel. Humidity 15 - 95 %, no condensation, Atmosph. Pressure 700 - 1060 hPa
    Power Consumption
    up to 80 VA
  • Parameters

    FVC
    ATI, BEV, EOTV, FEF10, FEF25, FEF 2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax, FEV1, FEV1/FEV6, FEV1/FVC, FEV1/FVC6, FEV1/VC, FEV1/VCmax, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, t0, VCmax
    FVL
    ATI, BEV, CVI, E50/150, EOTV, FEF10. FEF25, FEF2575, FEF2575_6, FEF40, FEF50, FEF50/FVC, FEF50/VCmax, FEF60, FEF75, FEF75-85, FEF80, FET, FET25-75, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FEV6, FEV.75/FVC, FEV.75/VCmax, FEV1, FEV1/FEV6, FEV1/FIV1, FEV1/FIVC, FEV1/FVC, FEV1/VC, FEV1/VCmax, FEV3/FVC, FEV3/VCmax, FEV3, FEV6, FIF25, FIF2575, FIF50, FIF50/FEF50, FIF75, FIV.25, FIV.5, FIV1, FIVC, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MIF25, MIF50, MIF75, MMEF, MMIF, MTC1, MTC2, MTC3, MTCR, PEF, PEFT, PIF, t0, VCmax
    SVC
    ERV, IC, IRV, Rf, VC, VCex, VCin, VCmax, VT
    MVV
    MVV, MVV6, MVVtime, Rf, VCext, VT
    DLCO
    BHT, COHb, ColBarVol, CO Conc, HE Conc, O2 Conc, Anatomic Dead Space, System Dead Space, Discard Volume, DLadj, DLadj/VA, DLCO, DLCO/VA (KCO), ERV, FA CO, FA HE, FE CO, FEV1/FVC, FI CO, FI HE, FRC sb, FRC Cor, Hb, tI, Kroghs K, PaO2, RV sb, RV Cor, RV/TLC sb, RV/TLC Cor, TLC sb, TLC Cor, TLCO, VA sb, VA Cor, VCext, VCmax, Vd, VI, VT
  • Predicted normal values Spirometry

    GLI
    Quanjer 2012, Stanojevic 2009
    North America
    Crapo 1981, Dockery (Harvard) 1993, Eigen 2001, Gutierrez (Canada) 2004, Hsu 1979, Knudson 1983, Knudson 1976, Morris 1971 & 1976, NHANES III (Hankinson) 1999, Polgar 1971
    Latin America
    Chile 2010, Chile (Pediatrics) 1997, Pereira 1992, Pereira 2006/2008, Pérez-Padilla (PLATINO) 2006, Pérez-Padilla (Mexico)2001, Pérez-Padilla (Mexico, Pediatrics) 2003
    Europe
    ERS (ECCS, EGKS, Quanjer) 1993, Garcia-Rio (SEPAR) 2013, Falaschetti 2004, Forche (Austria) 1988 & 1994, Klement (Russia) 1986, Roca (Spain, SEPAR) 1982, Rosenthal 1993, Sapaldia (Switzerland) 1996, Vilozni 2005, Zapletal 1977, Zapletal 2003
    Europe Scandinavia
    Berglund Birath (Sweden) 1963, Finnish 1982 (1998), Gulsvik (Norway) 1985, Hedenström 1985 & 1986, Langhammer (Norway) 2001, Kainu (Finland), 2016, Nystad 2002
    Australia
    Gore Crockett 1995, Hibbert 1989
    Asia
    Chhabra (India) 2014, Dejsomritrutai (Thailand) 2000, Indonesia 1992, IP (China, HongKong) 2000 & 2006, JRS 2001 & 2014
    Africa
    Mengesha (Ethiopia), 1985
  • Predicted normal values DLCO

    North America
    Ayers 1975, Burrows 1961, Crapo 1981 & 1982, Knudson 1987, McGrath & Thompson 1959, Miller 1980, Gutierrez(Canada) 2004, NHANES (Neas) 1996, Polgar 1971
    Latin America
    Vazquez Garcia (ALAT) 2016, Gochicoa 2019
    Europe
    Stanojevic (GLI) 2017, ERS ECCS/EGKS 1993, Zapletal 1977, Roca 1990 & 1998, Hedenström 1985 & 1986, Gulsvik 1992,Klement (Russia) 1986ERS (Quanjer) 1993, Zapletal 1977, Roca 1990 & 1998, Hedenström 1985 & 1986, Gulsvik 1992, Klement (Russia) 1986
    Other
    Pereira 2008, Thompson 2008, Kim 2012, Chhabra (India) 2015), Ip (China, HongKong) 2007, JRS (Japan) 2001
  • Flow/Volume Sensor

    Type
    Ultrasonic transit time
    Flow Range
    ± 16 l/s
    Flow Resolution
    4 ml/s
    Flow Accuracy (except PEF)
    ± 2% or 0.02 l/s
    Volume Resolution
    1 ml
    Volume Accuracy
    ± 2% or 0.050 l
    PEF Accuracy
    ± 5% or 0.200 l/s
    MVV Accuracy
    ± 5% or 5 l/min
    Resistance
    ~ 0.3 cm H2O/l/s at 16 l/s
    Sample Rate
    400 Hz (converted and stored with 200 Hz)
  • Gas Sensor CO

    Type
    Non-dispersive infrared
    Range
    0 to 0.35%
    Resolution
    0.0001% (1 ppm)
    Accuracy
    ± 0.0015% (15 ppm)
  • Tracer Gas Sensor Helium

    Type
    Ultrasonic transit time
    Range
    0 to 50%
    Resolution
    0.02%
    Accuracy
    0.05%
  • Ordering Information Devices

    Part Numbers
    Description
    3100-1
    EasyOne Pro LAB Respiratory Analysis System
  • Ordering Information Accessories

    Part Num
    Description
    2050-1
    Case of 50 Spirette mouthpieces
    2050-5
    Case of 200 Spirette mouthpieces
    2050-10
    Case of 500 Spirette mouthpieces
    3050-1
    Case of 50 DLCO Barriette for EasyOne Pro
    3050-2
    Case of 100 DLCO Barriette for EasyOne Pro

Spirette FA Pro/LAB Specifications

  • Product

    Product
    Spirette FA Pro/LAB
    Compatible with ndd products
    EasyOne Pro and EasyOne Pro/LAB with Software Version V03.07.01.09 (or higher)
    Compatible with filter
    U.S. & International customers: To learn more about compatible inline filter solutions available in your region, please use the contact us form.
    Transport and storage conditions
    Temperature: –20 to 50° C Humidity: 5 to 95% Pressure: 400 to 1060 hPa
    Dimensions
    31 x 38 x 141 mm
    Weight
    11g
    Material Spirette FA Pro/LAB
    Linear Low-Density Polyethylene, Polypropylene (LLDPE and PP)
    Material Bag
    Polyethylene

Accessories

Get in touch today!

Get a quote
Join the ndd family today.

Be the first to learn about special offers, product news, and industry updates!

Sign up today!